5110XM-PR 4/96
ADEMCO 5110XM PROGRAMMING FORM
FIELD FUNCTION PROGRAMMED VALUES
[ ] = Default Value
SYSTEM SETUP (
*
20,
*
27)
*
20 MASTER CODE ÊÊÊÊ ÊÊÊÊ ÊÊÊÊ ÊÊÊÊ [5] [1] [1] [0]
Enter 4 digits, 0-9
Note:
Master code for installer usage only. When remote keypad
installed, program user 2 code for system's principal user.
*
27 OUTPUT TO LONG RANGE RADIO
ÊÊÊÊ
[0]
0 = no; 1 = yes
If yes, dialer reports to PRIMARY No. (field
*
47) will also be sent via LRR. All
dialer and LRR reports will be in Contact ID format (overriding field
*
46
selection).
This option has not been evaluated by UL and must be programmed to "0."
MISCELLANEOUS OPTIONS (
*
30-
*
34)
*
30 ALARM BELL TIMEOUT
ÊÊÊÊ
[0]
0 = none; 1= 4 min; 2 = 8 min; 3 = 12 min; 4 = 16 min
For fire installations, bell must be programmed for option "0," "2," "3," or "4."
*
31 AUXILIARY RELAY TIMEOUT
ÊÊÊÊ
[4]
0 = none; 1= 4 min; 2 = 8 min; 3 = 12 min; 4 = 16 min
*
32 SUPERVISORY ON OPEN/SHORT
ÊÊÊÊ
[0]
0 = Trouble on Open/Supv on Short; 1 = Supv on Open/Supv on Short
*
33 BACK-UP DIALER PULSE/TONE ÊÊÊÊ [0]
0 = Pulse Dial; 1 = Tone Dial
*
34 AUXILIARY RELAY FUNCTION
ÊÊÊÊ
[1]
0 = Trouble/Supv; 1 = Alarm (silenced by: SILENCE/RESET key press, or code
+ OFF entry); 2 = Smoke Detector Reset; 3 = Battery Save; 4 = Alarm (silenced
by: code + #67 entry).
Notes: 1.
Requires remote keypad for "code + OFF" or "code + #67" entry.
2.
When function "1" or "4" is selected, program fields
*
85 and
*
86 to
select zones which will trigger AUX RELAY. When function "1" is
selected, program AUX RELAY timeout in field
*
31.
Entry of a number other than one specified will give unpredictable results.
DIALER PROGRAMMING (
*
40-
*
50) In fields
*
40,
*
41,
*
42, enter up to the number of digits shown. Do not fill
unused spaces. Enter 0-9; #+11 for '
*
'; #+12 for '#'; #+13 for a pause.
*
40 PABX ACCESS CODE ÊÊÊÊ ÊÊÊÊ ÊÊÊÊ ÊÊÊÊ
Enter up to 4 digits.
If fewer than 4 digits entered, exit by pressing
*
(and press 41, if entering next
field). To clear entries from field, press
*
40
*
.
*
41 PRIMARY PHONE No. ÊÊÊÊ ÊÊÊÊ ÊÊÊÊ ÊÊÊÊ ÊÊÊÊ ÊÊÊÊ ÊÊÊÊ ÊÊÊÊ ÊÊÊÊ ÊÊÊÊ ÊÊÊÊ ÊÊÊÊ
Enter up to 12 digits. If fewer than 12 digits entered, exit by pressing
*
(and
press 42, if entering next field). To clear entries from field, press
*
41
*
.
*
42 SECONDARY PHONE No. ÊÊÊÊ ÊÊÊÊ ÊÊÊÊ ÊÊÊÊ ÊÊÊÊ ÊÊÊÊ ÊÊÊÊ ÊÊÊÊ ÊÊÊÊ ÊÊÊÊ ÊÊÊÊ ÊÊÊÊ
Enter up to 12 digits. If fewer than 12 digits entered, exit by pressing
*
(and
press 43, if entering next field). To clear entries from field, press
*
42
*
.
*
43 SUBSCRIBER ACCT No. ÊÊÊÊ ÊÊÊÊ ÊÊÊÊ ÊÊÊÊ
Enter 0-9; #+11 for B; #+12 for C; #+13 for D; #+14 for E; [#+15 for F]. Enter
*
as 4th digit, if 3+1 reporting is used.To clear entries from field, press
*
43
*
.
Examples:
For Acct No. 1234, enter: 1ÊÊ Ê2Ê Ê3ÊÊ 4ÊÊ
For Acct No. B234, enter: #+11 #+11 Ê2Ê Ê3ÊÊ 4ÊÊ
For Acct No. 123, enter: , 1, , 2, , 3, , T 1ÊÊ Ê2Ê Ê3ÊÊ ÊkÊ
Previous Menu
Vedere la pagina 0
1 2 3 4

Sommario

Pagina 1 - Examples:

5110XM-PR 4/96ADEMCO 5110XM PROGRAMMING FORMFIELD FUNCTION PROGRAMMED VALUES[ ] = Default ValueSYSTEM SETUP (*20, *27)*20 MASTER CODE ÊÊÊÊ ÊÊÊÊ ÊÊÊ

Pagina 2 - Dual Reporting)

ÐbÐ*45 MAIN DIALER PULSE/TONE ÊÊÊÊ [0]0 = Pulse Dial; 1 = Tone Dial*46 REPORT FORMAT ÊÊÊÊ [0] also see field *27.0 = 3+1, 4+1 ADEMCO L/S STANDARD 6

Pagina 3

ÐcÐ*57 ZONE TYPE 18 DELAY ENABLE ÊÊÊÊ [1]0 = Disable Delay (ignore delay programmed in field *78)1 = Enable Delay (use delay programmed in field

Pagina 4 - A DIVISION OF PITTWAY CORP

5110XM-PR 4/96*78 ZONE TYPES 17 & 18 DELAYÊÊÊÊ ÊÊÊÊ[00]00-99 seconds.Note: Zone type 18 delay must be enabled in field *57.Combined sensor and