General
4137AD Addressable
Fixed-Word Console
5137AD Addressable
Alpha Console
6139 Deluxe
Addressable Alpha
Console
The Control supplies up to 750 mA of auxiliary power for remote consoles, polling
loop devices and/or other auxiliary devices such as motion detectors or 4-wire
smoke detectors*.
The Controls support, independent of auxiliary power considerations, up to 16
addressable remote consoles (4137AD,
5137AD, 6139).
Up to twelve (12) 4137AD or eight (8) 5137AD or seven (7) 6139 consoles can
be powered from the auxiliary power output provided that the total current drawn
from this output does not exceed 750 mA. Keep this in mind when adding
remote consoles so you don’t overdraw current from the panel. This woukf result
in a battery which does not charge properly or possibly a tripped auxiliary solid
state circuit breaker.
If the auxiliary load is determined to be greater than 750 mA, then additional
consoles can be powered from a separate power supply. Refer to the
POWERING ADDITIONAL CONSOLES paragraph
for a diagram that shows how
to make connections to the separate power supply.
● 4-wire smoke detectors cannot be used in UL Listed applications.
Equipped with a liquid crystal display (LCD)
using 2-digit numerics for zone
identification, and a set of pre-designated English language prompts, such as
“READY”, “NOT READY”, etc. for system status. Keys are backlit. A built-in alarm
sounder is also included, eliminating the need for a separate indoor sounder. DIP
switch selectable ID number, which allows console to display status of the
partition to which it is assigned. 60mA current draw.
-
Equipped with a programmable 2-Iine, 32-character (16 characters per line),
backlit alphanumeric LCD for complete zone identification in English language (if
descriptors are programmed). Keys are also backlit.
An alarm sounder is built in, eliminating the need for a separate indoor sounder.
DIP switch selectable ID number, which allows console to display status of the
partition to which it is assigned.
90mA current draw.
The 6139 Remote Consoles are keypad addressable (no DIP switches) console,
and features a red “ARMED LED which lights when the system is anneal,and a
green “READY” LED* which lights when the system is ready to be armed (no
zone faults present). This console also features display backlighting. The keypad
on this console is located behind a decorative door, and is continuously backlit for
ease in use. The keypad also features special panic keys, labeled A, B, & C (the
D key is not used), which are the equivalent to the panic pairs of keys l/Q, Q/#, &
3/# respectively. Note that these keys must be held down for at least 2 seconds
to activatean alarm.
* Note that the function of this LED (system ready)differs from the function of the
green LED on Ademco’s4137AD & 5137AD consoles.
The console can be surface mounted directly to a drywall, or to a single or double
gang electrical box. For flush mounting to drywall, use the optional6139TRK
flush mount kit.
100mA current draw.