4140XM/5130XM/4130XM
INSTALLATION
INSTRUCTIONS .
A complete VISTA Technical Reference
Manual that can unlock the full power of
the VISTA XM System is a&table.
See inside front cover for more
information.
WWW.DIYALARMFORUM.COM
Vedere la pagina 0
1 2 3 4 5 6 ... 29 30

Sommario

Pagina 1 - WWW.DIYALARMFORUM.COM

‘1 - VISTA XM SERIES 0 4140XM/5130XM/4130XM INSTALLATION INSTRUCTIONS . A complete VISTA Technical Reference Manual that can unlock the full

Pagina 2

ZONE 1 When programmed as an EOLR supervised FIRE zone (type 09 in program field ‘02). up to three 2-wire smoke detectors can be used

Pagina 3

- PASSIVE INFRARED MOTION DETECTORS - GENERAL INFORMATION. Select a mounting site with the following notes in mind: Best coverage wil

Pagina 4

IV. MOUNTING AND POWERING THE SYSTEM Note that field wiring to these controls/consoles must be completed before the controls/consoles

Pagina 5

- POWERING THE SYSTEM - PRIMARY. POWER Power to the 4140XM Control panel is supplied by a Plug-In DC Power Pack, 1360, which is r

Pagina 6

I AUXILIARY DEVICE CURRENT DRAW WORKSHEET DEVICE OF UNITS I TOTAL CURRENT (4137 Console ’ t CURRENT I # 1 60 mA 5137 Console 90 mA 4146

Pagina 7

V. SYSTEM OPERATION L SECURITY ACCESS CODES - The VISTA XM System allows up to 22 security access codes to be assigned, each ident

Pagina 8

VI. SYSTEM COMMUNICATIONS The 4171XT-XM Dialer Board is required for polling loop and/or wireless zone expansion, and for office initia

Pagina 9

CONTACT ID REPORTING This is the only format that can identify all 64 protection zones by their unique zone (Contact) ID numbers, a

Pagina 10

VIII. TESTING .THE SYSTEM USING TEST MODE After the installation is completed, the Security System should be thoroughly tested as fol

Pagina 11

IX. SPECIFICATIONS 4140XM CONTROL Physlcal: Width: 12 inches (305mm) Height: 12 inches (305mm) Depth:. 3 inches (76mm) Electrlcal: VOLTAGE I

Pagina 12

CONGRATtiLATIONS and WELCOME to the VISTA XM FAMILY! The purpose of these Installation Instructions is to give you, the installer, a brief overv

Pagina 13

L - 18 - WWW.DIYALARMFORUM.COM

Pagina 14

c=n I - 19 - WWW.DIYALARMFORUM.COM

Pagina 15

--w-M s-j - I I - RDIBLK L . r ““, * I _ r I I I! Z 3RN I - 20 - WWW.DIYALARMFORUM.COM

Pagina 16

4130XM/4140XM/5130XM PROGRAMMING INSTALLER CODE ‘Qo (EN=R W MASTER CODE wl (ENTER GO) ZONES RESPONSE TYPE 02 (ENTER 00.10) ZONES 001wwndzm 019EE

Pagina 17

PRIORITY ZONE ‘39 m CHANNEL ASSIGNED .61 (Enter 01-15: 00 I 01.31 (oonauzonerare byWb) TO EACH ?ONE 2 WCOdnDorbng) USER 0 10 11 12 13 (4 1

Pagina 18

4+2 EXPANDED 73 71 FORMAT ZONES 1st DIGIT 2nd DlGlT Q-16 REPORTS ALRM 29 TRBL 210 (Enter00- 15: 00.nochmnel BYPASS 211 fepoM3) ALRM RESTA 212

Pagina 19

DESIGNATE RIGHT ZONE USAGE (SEE -06 FOR CHOICES) 93343536373639 40 l 110 zN33-40 lrrIrll~ 41 42 43 44 45 46 47 ‘6 ‘111 zN41-48 I IIII

Pagina 20

“FEDERAL COMMUNICATIONS COMMISSION (FCC) STATEMENT” This equipment has been tested to FCC requirements and has been found acceptable for

Pagina 21

- 26 - WWW.DIYALARMFORUM.COM

Pagina 22

WARNING THE LIMITATIONS OF THIS ALARM SYSTEM While this system is an advanced design security system, it does not offer guaranteed

Pagina 23

Dear Valued Customer To help provide you with the best possible products and service, please take a few minutes.to complete this surv

Pagina 24

ADEMCO Llmlted Warrclnty Alarm Device Manufacturing Company, a Division of Pittway Corporation, and its divisions, subsidiaries and affi

Pagina 25

9296- L6L 15 AN ‘l=SOb =!a l~W~!lry 081 33ss3t1aav AQ (31Vd 39 7llM 30VlSOd LGLL 1 AN ‘EISSOAS . SSL ‘ON AWEld SW-I3 lStllj ClW3 AldM SS

Pagina 26

I. II. Ill. IV. V. VI. VII. TABLE OF CONTENTS GENERAL INFoRMATION.. ... 4 ZONE TY

Pagina 27 - 004-000

I. GENERAL INFORMATION THE VISTA CONTROLS The VISTA XM Controls are microprocessor based programmable systems and feature EEROM memory t

Pagina 28

II. ZONE TYPE DEFINITIONS Each tone must be assigned to a zone type, which defines the way in which the system responds to faults i

Pagina 29

111. (A) SYSTEM CONFIGURATION (ZONES) - BASIC 9 HARD-WIRED ZONES - - ZONE 1 This zone haa a 350 millisecond re6pon6e and can be assign

Pagina 30

- 2-WIRE POLLING (Zones 10 GENERAL INFORMATION To expand the system using a P-wire polling loop and remote point modules (RPMs), a 417