
7:
8:
9:
10:
11:
12:
13:
14:
Continuous Auxiliary/Remote Console Power
(R~): +12 VDC at 400 mA
max.
Alarm relay activation signal.
Zone 6(+)=*
Zones 6 and 7 Return.
Zone 7(+).*
Zone 8(+).*
Zones 8 and 9 Return/Auxiliary Power (-).
Zone 9(+)
- N.C. Zone, Fast Response (15 Msec).
* Zone that is programmable for use
as a N.C. sensor loop or as end-of-
line resistor supervised N.O./N.C. sensor loop.
Alarm Relay Board Connections:
Terminal
Usage
1
12V (+) (must be wired to TB2-5 on Control).
2 12V (-) (must be wired to TB2-6 on Control).
3 Siren (-)
4
Siren (+)
5
Not used.
6 Not used.
7
Trigger (must be wired to TB2-8 on Control).
‘Digital Communication Interface Board Connections** (Phone Line Interface):
Terminals
1: Ground Start Output (to BLUE LEAD on No. 675 Ground Start Module).
2: Incaning Phone Line (TIP).
3:
Incoming Phone Line (RING).
4: Handset (RING).
5:
Handset (TIP).
Warning: To prevent the risk of shock,
disconnect telephone line at Telco
jack before servicing the unit.
**
The Digital Communication Interface board (4171XT) must be mounted onto the
main circuit board by the installer (see the separate Supplementary
Installation Instructions that hav”ebeen provided).
15
Commenti su questo manuale