- 8 -
Field Function
Programmed Values[ ] = Table 1 Default Value
✱
75
RF XMTR LO BAT RST RPT CODE
|
[1,0]
✱
76
TEST RESTORE RPT CODE
|
[0,0]
OUTPUT AND SYSTEM SETUP (
*
80–
*
92)
✱
80
✱
81
DEVICE PROGRAMMING MENU
MODE
ZONE LISTS MENU MODE
Program *80 and *81 only if Powerline Carrier Devices or chime
by zone are to be used. See procedure later in this manual.
✱
83
ENHANCED SEQUENTIAL MODE See procedure later in this manual.
✱
84
ASSIGN ZONE VOICE
DESCRIPTOR
See procedure later in this manual.
✱
85
RECORD CUSTOM VOICE
DESCRIPTOR
See procedure later in this manual.
✱
87
AUX FUNCTION/ 1-BUTTON
PAGING
[0]
0 = Aux key performs defined function (macro);
1 = Aux key sends message to pager or voice message to follow me
system phone number.
If 1, you must also select an option 6-9 in field *49 for the pager or 10-
13 for the follow me system announcement.
✱
88
PAGER CHARACTERS
Up to 16 digits can be entered that will appear in front of the 7-digit
pager message sent by the control (either upon system event or upon
pressing AUX key [if programmed for paging]; see field *87 and *49 for
other options regarding the paging feature). See the Installation
Instructions (fields *87, *88 and *49) for full descriptions of the paging
feature. You do not need to fill all 16 digits (press [*] to advance to
next field). To clear entries, enter *88*.
To enter “*” = [#] + [11]; To enter “#” = [#] + 12]
To enter 2-second pause = [#] + [13] (some pagers require an
additional delay [pause] in order to receive the entire message)
✱
89
EVENT LOG 80% FULL RPT CODE
|
[0,0]
✱
90
EVENT LOGGING
[15]
0 = None; 1 = Alarm/Alarm Restore; 2 = Trouble/Trouble Restore;
4 = Bypass/Bypass Restore; 8 = Open/Close.
Example:
To select “Alarm/Alarm Restore”, and “Open/Close”, enter 9
(1 + 8); To select all, enter #15.
Note:
System messages are logged when any non-zero selection is made.