This section provides instructions for mounting the control cabinet, and
installing the cabinet lock (if used). Also included in this section are w
instructions for the following
Installing the main PC board.
Standard phone line connections.
Installing the back-up battery in the cabinet.
c Connecting the AC transformer.
s Making earth ground connections.
Mounting the Cabinet
Mount the control cabinet to a sturdy wall using fasteners or anchors (not
supplied), in a clean, dry area which is not readily accessible to the general
public. Four mounting holes are provided at the back of the cabinet.
Installing the Lock (if used)
Use an Ademco No. N6277 Cam
(Retainer Clip).
Note: The cabinet can be closed
screws in the cover’s edge.
Lock and No. N6277–1 Push-On Clip
and secured wit bout a lock by using 2
a
o
LUXEU
3
RErumn CLw
(@
‘. :
. . .
‘.. +
1.
2.
3.
CAmm Doon 90?70!4
Figure 1. Installing The Cabkwt Lock
Remove the cabinet door. It is
easily removable for servicing
and is easily re-installdd.
Remove the lock knockout
from the control cabinet door.
Insert the key into the lock.
Position the lock in the hole w
making certain that the latch
will make contact with the
latch bracket when the door is
closed.
Hold the lock steady, and in-
sert the retainer clip into the
retainer slots. Position the
clip as illustrated in order to
permit easy removal.